Analisa Minyak Transformator Daya 60 MVA Menggunakan Pengujian Dissolve Gas Analysis

Authors

  • Ermawati Program Studi Teknik Elektro, Sekolah Tinggi Teknologi Pekanbaru
  • Yolnasdi Program Studi Teknik Elektro, Sekolah Tinggi Teknologi Pekanbaru
  • Hanifulkhair Program Studi Teknik Elektro, Sekolah Tinggi Teknologi Pekanbaru
  • Engla Harda Arya Program Studi Teknik Elektro, Sekolah Tinggi Teknologi Pekanbaru
  • Sely Kusuma Anggraeni Program Studi Teknik Elektro, Sekolah Tinggi Teknologi Pekanbaru

DOI:

https://doi.org/10.31849/2yz31371

Keywords:

Minyak Transformator, Dissolve Gas Analysis (DGA), Transformator Daya

Abstract

Transformator dapat mengalami kondisi abnormal, pemicunya dapat berasal dari gangguan internal maupun eksternal dari transformator tersebut. Gangguan eksternal berupa gangguan hubung singkat di luar transformator. Arus gangguan ini cukup besar dapat memicu timbulnya panas pada minyak transformator. Pendeteksian kerusakan transformator salah satunya dengan pengujian minyak DGA (Dissolve Gas Analysis) yang dapat mengetahui kadar atau nilai dari gas-gas yang terlarut dalam minyak transformator. Gas-gas tersebut timbul akibat ketidaknormalan pada transformator kemudian dilakukan analisa menggunakan metode TDCG (Total Dissolved Combustible Gases),.  metode Key Gas, dan metode Duval Triangle. Sampel minyak transformator yang digunakan diambil dari Tranformator Daya 60 MVA Gardu Induk Keramasan. Hasil pengujian 1 TDCG sebesar 5622,30 ppm, pengujian 2 TDCG sebesar 5896,30 ppm dan pengujian 3 TDCG sebesar 11136,78 ppm berdasarkan limit IEEE TDCG > 4630 ppm termasuk kondisi 4 yang menunjukkan dekomposisi yang berlebihan. Operasi lanjutan dapat mengakibatkan kegagalan transformator. Metode Key Gas dan Duval Triangle menunjukan Termal Fault temperature antara 300oC dan 700oC, sehingga mengakibatkan pemanasan minyak isolasi dan kertas isolasi transfomator.

References

[1] Agus Siswanto1, Abdul Rohman2, et al,” Analisis Karakteristik Minyak Transformator Menggunakan Pengujian Dissolved Gas Analysis (DGA) Pada IBT 1 Gardu Induk,” Jurnal Ilmiah Foristek Jurusan Teknik Elektro UNTAD, Vol 12, No. 1, Maret 2022,.

[2] Badaruddin, Fery Agung Firdianto, “Analisa Minyak Transformator Pada Transformator Tiga Fasa Di PT X”, Jurnal Teknologi Elektro, Universitas Mercu Buana, Vol.7 No.2 Mei 2016

[3] IEEE Std C57.104™-. IEEE Guide for the Interpretation of Gases, New York, Generated in Oil-Immersed Transformers. 2008.

[4] IEC 60599,. Mineral oil-filled electrical equipment in service – Guidance on the interpretation of dissolved and free gases analysis, 2015..

[5] I. C. Anghel and E. Gatman, "Establishment of the accessibility limit for the furans content of the electrical insulating oils in service," 2019 International Conference on ENERGY and ENVIRONMENT (CIEM), pp. 479-483, doi: 10.1109/CIEM46456.2019.8937636. 2019.

[6] L. Gu et al., "Dissolved Gas Analysis in Camellia Insulating Oil during Thermal Ageing Test," 2019 2nd International Conference on Electrical Materials and Power Equipment (ICEMPE), pp. 495 498, doi: 10.1109/ICEMPE.2019.8727299, 2019,

[7] Marsudi, Djiteng..Pembangkitan Energi Listrik, Jakarta, Erlangga, 2011

[8] PT PLN (Persero) Tim Penulis, Buku Pedoman Pemeliharaan Transformator Tenaga. (Keputusan Direksi PT PLN (Persero) No. 0520 2K/DIR/2014),. Jakarta: 2014

[9] PT PLN (Persero) UIP3BS,. Alur Langkah Kerja Pengujian DGA dengan SHIMADZU Model GC-14. Pekanbaru: PT PLN (Persero), 2019

[10]SPLN T5.004-5, Pedoman Uji Karakteristik Minyak Insulasi dan Uji DGA, Bagian 5 : Interprestasi Hasil Uji DGA, Jakarta, PT PLN (Persero), 2017

[11]R. P. Singh, A. V. Sonawane, M. S. Satpute, D. Y. Shirsath and M. P. Thakre, "A Review on Traditional Methods of Condition Monitoring of Transformer," 2020 International Conference on Electronics and Sustainable Communication Systems (ICESC), pp. 1144-1152, 2020.

[12] Z. Lixing, Z. Zhuodong, Z. Pengfei and L. Jia, "Study on Analysis and Prediction of Transformer Overheating Fault Based on Chaos Theory of Oil Chromatogram," 2018 International Conference on Engineering Simulation and Intelligent Control (ESAIC),pp.92-97, 2018.

Downloads

Published

2025-12-31

Issue

Section

Articles

How to Cite

[1]
“Analisa Minyak Transformator Daya 60 MVA Menggunakan Pengujian Dissolve Gas Analysis”, SainETIn, vol. 10, no. 1, pp. 19–29, Dec. 2025, doi: 10.31849/2yz31371.